{"id":7814,"date":"2025-12-22T23:40:19","date_gmt":"2025-12-22T23:40:19","guid":{"rendered":"https:\/\/demo.marvx.com\/mrsa\/?post_type=product&#038;p=7814"},"modified":"2025-12-22T23:40:43","modified_gmt":"2025-12-22T23:40:43","slug":"ventilator","status":"publish","type":"product","link":"https:\/\/mrsa-medical.net\/ar\/product\/ventilator\/","title":{"rendered":"VENTILATOR"},"content":{"rendered":"<p style=\"direction: ltr; text-align: left;\"><strong>By <\/strong><strong>Tecme Neumovent<\/strong><\/p>\n<p style=\"direction: ltr; text-align: left;\"><strong>Model: <\/strong><strong>TS<\/strong><\/p>\n<p style=\"direction: ltr; text-align: left;\"><strong>Country<\/strong><strong> : <\/strong><strong>America<\/strong><\/p>\n<p style=\"direction: ltr; text-align: left;\"><strong>For Adult, Pediatric, Neonate<\/strong><\/p>\n<p style=\"direction: ltr; text-align: left;\"><strong>FDA<\/strong><strong>\u00a0 <\/strong><\/p>\n<p style=\"direction: ltr; text-align: left;\"><strong>Technical Specifications :-<\/strong><\/p>\n<ul style=\"text-align: left;\">\n<li style=\"direction: ltr;\"><strong>12 Inch Touch Screen <\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>working for 2.5 hours<\/strong> <strong>continuously<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>27<\/strong> <strong>hours of trend storage<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>Proximal flow sensor<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>The device works with high accuracy on children less than 1 kg<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>Use Expiratory Valve<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>The device has 10 different patterns for newborns<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>The device is low in consumables as it works with sterilizable and reusable<\/strong><\/li>\n<\/ul>\n<p style=\"direction: ltr; text-align: left;\"><strong>\u00a0<\/strong><\/p>\n<p style=\"direction: ltr; text-align: left;\"><strong>OPERATIVE MODES (according to patient category)<\/strong><\/p>\n<ul style=\"text-align: left;\">\n<li style=\"direction: ltr;\"><strong>vcv- Volume Control (Assist \u2013 Control)<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>PCV- Pressure Control (Assist- Control)<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>PSV &#8211; Pressure Support.<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>CPAP &#8211; Continuous Positive Airway Pressure.<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>SIMV (VCV) + PSV.<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>SIMV (PCV) + PSV.<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>MMV + PSV- Mandatory Minute Ventilation (Dual mode).<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>PSV +Tidal Volume Assured.<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>APRV- Airway Pressure Release Ventilation.<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>NIV- Non-Invasive Ventilation (With Leak Compensation).<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>PRVC \u2013Pressure Regulated Volume Control (Dual mode).<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>TCPL <\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>TCPL (SIMV)+PSV<\/strong><\/li>\n<\/ul>\n<p style=\"direction: ltr; text-align: left;\"><strong>for Intensive care and NEONATAL ICU<\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p style=\"direction: ltr; text-align: left;\"><strong>By <\/strong><strong>Tecme Neumovent<\/strong><\/p>\n<p style=\"direction: ltr; text-align: left;\"><strong>Model: <\/strong><strong>TS<\/strong><\/p>\n<p style=\"direction: ltr; text-align: left;\"><strong>Country<\/strong><strong> : <\/strong><strong>America<\/strong><\/p>\n<p style=\"direction: ltr; text-align: left;\"><strong>For Adult, Pediatric, Neonate<\/strong><\/p>\n<p style=\"direction: ltr; text-align: left;\"><strong>FDA<\/strong><strong>\u00a0 <\/strong><\/p>\n<p style=\"direction: ltr; text-align: left;\"><strong>Technical Specifications :-<\/strong><\/p>\n<ul style=\"text-align: left;\">\n<li style=\"direction: ltr;\"><strong>12 Inch Touch Screen <\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>working for 2.5 hours<\/strong> <strong>continuously<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>27<\/strong> <strong>hours of trend storage<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>Proximal flow sensor<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>The device works with high accuracy on children less than 1 kg<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>Use Expiratory Valve<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>The device has 10 different patterns for newborns<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>The device is low in consumables as it works with sterilizable and reusable<\/strong><\/li>\n<\/ul>\n<p style=\"direction: ltr; text-align: left;\"><strong>\u00a0<\/strong><\/p>\n<p style=\"direction: ltr; text-align: left;\"><strong>OPERATIVE MODES (according to patient category)<\/strong><\/p>\n<ul style=\"text-align: left;\">\n<li style=\"direction: ltr;\"><strong>vcv- Volume Control (Assist \u2013 Control)<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>PCV- Pressure Control (Assist- Control)<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>PSV &#8211; Pressure Support.<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>CPAP &#8211; Continuous Positive Airway Pressure.<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>SIMV (VCV) + PSV.<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>SIMV (PCV) + PSV.<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>MMV + PSV- Mandatory Minute Ventilation (Dual mode).<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>PSV +Tidal Volume Assured.<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>APRV- Airway Pressure Release Ventilation.<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>NIV- Non-Invasive Ventilation (With Leak Compensation).<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>PRVC \u2013Pressure Regulated Volume Control (Dual mode).<\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>TCPL <\/strong><\/li>\n<li style=\"direction: ltr;\"><strong>TCPL (SIMV)+PSV<\/strong><\/li>\n<\/ul>\n<p style=\"direction: ltr; text-align: left;\"><strong>for Intensive care and NEONATAL ICU<\/strong><\/p>","protected":false},"featured_media":7859,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[421,422],"product_tag":[],"class_list":{"0":"post-7814","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-intensive-care-units","7":"product_cat-ventilator","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/mrsa-medical.net\/ar\/wp-json\/wp\/v2\/product\/7814","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mrsa-medical.net\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/mrsa-medical.net\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/mrsa-medical.net\/ar\/wp-json\/wp\/v2\/comments?post=7814"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mrsa-medical.net\/ar\/wp-json\/wp\/v2\/media\/7859"}],"wp:attachment":[{"href":"https:\/\/mrsa-medical.net\/ar\/wp-json\/wp\/v2\/media?parent=7814"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/mrsa-medical.net\/ar\/wp-json\/wp\/v2\/product_brand?post=7814"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/mrsa-medical.net\/ar\/wp-json\/wp\/v2\/product_cat?post=7814"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/mrsa-medical.net\/ar\/wp-json\/wp\/v2\/product_tag?post=7814"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}